Print Back
Sleeve bearing fans are also available.
All fans can be specified with lead wires or terminal connectors.

High air flow
Unit of Measure

Specifications

Bearing System

N/A Ball

Size L

N/A 162 mm6.4 in

Size W

N/A 150 mm5.9 in

Size D

N/A 55 mm2.2 in

Voltage

N/A 120.0 V

Frequency

N/A 50/60 Hz

Power

N/A 46/50 Watts

Current

N/A 0.35/0.40 A

Speed

N/A 2850/3300 rpm

Airflow (Q)

N/A 7.10 m³/min8.30 m³/min250.00 cfm293.00 cfm

Pressure (P)

N/A 16.00 mmAq20.00 mmAq0.63 inH2O0.79 inH2O

Noise

N/A 56/61 dBA

Range (VAC)

N/A 100~125

Standard Specifications

Dielectric Strength

N/A AC 1500V for 3 sec (<0.5mA allowable between lead and frame).

Insulation Resistance

N/A 100 Mohm Min @ DC 500V

Storage Temperature @ 65% Relative Humidity

N/A -40 to +80 ºC

Noise

N/A Measured at rated voltage at 1 meter distance in an anechoic chamber with a background noise of 16dBA max.

Operation Voltage

N/A ±10% of rated voltage

Vibration

N/A JIS C0040 amplitude 1.5mm frequency 10-55Hz, 1 hr per axis: X, Z, Y.

Shock

N/A JIS C0041 acceleration 100G, duration 6ms per axis: X, Z, Y.

Life

N/A Life expectancy is 50,000 hours for ball bearings or 30,000 hours for sleeve bearings @ 25ºC, 65% ±20% relative humidity continuous operation.

Safety

N/A Designed to meet UL, cUL, TUV, and CE certification. RoHS compliant.

Insulation

N/A Class B