GL MODULE COMMON SPECIFICATIONS
  • Temperature Range Assurance: The GL Module is guaranteed to operate within a temperature range of -40°C to 100°C (with the suggested maximum temperature on the radiating side).
  • PVC Coating: This product features a PVC coating that adheres to UL standards.
  • Silicone Comparison: Similar to the KE347 product. It’s important to note that only the lateral side is not fully sealed for moisture-proof and waterproof measures.
USAGE PRECAUTIONS FOR PELTIER MODULES
Unit of Measure

I Max

3.5 A

Max Voltage

2.1 V

Max. Operating Temp. at 27°

68 ºC

Q Max. at 27°

3.9 Watts